Sunday, December 28, 2014

HP Network Node Manager i Software—HP Business Service Management/Universal CMDB Topology Integration Guide

 

The HP Business Service Management (BSM) platform provides tools for managing the availability of applications in production, monitoring system performance, monitoring infrastructure performance, and proactively resolving problems when they arise.

The HP NNMi–HP BSM/UCMDB Topology integration populates NNMi topology into either the BSM Run-time Service Model (RTSM) or the UCMDB database. Each device and device component in the NNMi topology is stored as a configuration item (CI) in RTSM or UCMDB. BSM or UCMDB users and integrated applications can also see the relationships between NNMi managed layer 2 network devices and BSM-discovered or UCMDB-discovered servers, hosted applications, and more.
Additionally, the integration stores the identifier of populated CIs in the NNMi database. Uses for the CIs of the NNMi-managed devices include the following:

  • NNMi components in the MyBSM portal.
  • Path health views available from the BSM Real User Monitor (RUM).
  • Using the agent implementation of the HP NNMi—HPOM integration, and pointing to a BSM Connector, results in an HP NNMi–HP BSM Operations Management integration that associates incidents regarding NNMi-managed devices with BSM CIs.
  • The comprehensive relationships maintained by RTSM or UCMDB enable an NNMi operator to view the impact of a network access switch infrastructure failure on other supported devices and applications. The NNMi operator selects an incident or a node in NNMi and then enters a request for impacted CIs.

image

Full details are in this document http://support.openview.hp.com/selfsolve/document/KM00830093/binary/nnmi_integration_business_service_mgmt_10.00.pdf

Thursday, December 11, 2014

OMi Monitoring Automation

OMi Monitoring Automation(OMi M.A.) automates the configuration of monitoring for infrastructure and composite applications. It detects new instances of components, from servers to composite applications, and maps them to predefined management templates and “aspects” that model to the desired configuration and resource type.

 

image

Wednesday, December 10, 2014

HP OMi: How to connect an HP Operations agent

In this video, you will learn how to connect an HP Operations agent to OMi so you can monitor availability and performance and remediate issues on a monitored server.

image

OMi is the only product that dynamically and automatically discovers and correlates—even as the environment changes—three sets of data: event data that indicates infrastructure- or service-impacting issues, for more details check OMi data sheet  http://h20195.www2.hp.com/V2/GetDocument.aspx?docname=4AA2-3879ENW&cc=us&lc=en

Wednesday, March 5, 2014

Topology Based Correlation using OMi

“I have to write any article to my blog, I have to get back to my audience” this is what consumes my mind during the last year. Although I hadn’t wrote any articles but I had a wonderful challenging year. From time to time, I write articles but they are always saved in the draft.

So it is the time to be back again.

I have a test lab and I had seen some messages that was generated from my domain controller but those events should be taken care by many team; supposing we are in real scenario.

I have disk capacity issue in dive C where Active Directory DIT files are stored.

image

At the same time, the Active Directory team is monitoring domain controller with Active Directory related policies and they have been alerted with the below events.

image

We need to tell both admins which event are root cause and which event are symptoms.

I will select the four alerts and Click on “Relate Events”

image

Select the identified Root event.

image

You can see now the event are categorized as root and symptoms under (C)orrelation column.

image

When you open any of the events you can see the correlation on “Related Events” tab.

image

What I have just done, is just manual correlation.

I have apply the same concept but with automation based on OMi topology based event correlation which Checks the events associated with Health Indicators against Topology relations as in our case we have filesystem connected with node that hosts domain controller. So if events with HI associated with FileSystem and other events with HIs associated with DomainController the can be correlated with the presence of TBEC rule as below.

I will select the events that has the HIs as below.

Note: I have selected one more event related to Node, to ensure that I will have the right topology relations

 

image

Then Identified the root cause event.

image

Give the Rule Name and description

 

image

 

It is just fun to create correlation rules, and you can let your operators focus on root cause events.

Sunday, July 31, 2011

Configure OMW to forward all events to OMi

1- Configure OMW to forward all events to OMi

a- Create Server-Flexible Management Policy

---

TIMETEMPLATES
# none

RESPMGRCONFIGS
RESPMGRCONFIG DESCRIPTION "Forward all messages to HP OMi"
SECONDARYMANAGERS
ACTIONALLOWMANAGERS

MSGTARGETRULES
MSGTARGETRULE DESCRIPTION "forward all messages rule"
MSGTARGETRULECONDS
MSGTARGETRULECOND DESCRIPTION "forward all messages "
MSGTARGETMANAGERS
MSGTARGETMANAGER
TIMETEMPLATE "$OPC_ALWAYS"
OPCMGR IP 0.0.0.0 "dxb-bsm-01.mahmoudthoughts.com"
---
replace dxb-bsm-01.mahmoudthoughts.com with your OMi server.
 



image


b- Deploy the newly created policy to your OMW server and ensure it is enabled.


2- Configure HPOM Topology Sync


On BSM Console


Click Admin > Platform > Setup and Maintenance > Infrastructure Settings 


Under Select Context select Operations Management from Applications


image


Browse to Operations Management - HPOM Topology Synchronization Connection Settings Section


Type your OM Server Hostname, User, password and change other options as needed.


image


Run opr-startTopologySync.bat from BSM bin directory


%TOPAZ_HOME%\bin\opr-startTopologySync.bat



image


Check the result on Modeling Studio


Admin > ODB Administration > Modeling > Modeling Studio 


Select Views from Resource Type list


Select OM CI Collections  from Root > Operations Management


image


Click on Preview Icon


 


image


The Result should be the Node, Node Groups and Service Hierarchy





image


3- list the events forwarded by OMW


Click on Application > Operations Management


The list of events should be displayed under Event Perspective


image





In the video below I captured 30 seconds on generating test messages from OMW and how fast it shows in OMi


Message Sync between OMW and OMI